Types & Configurations
Support grid (upflow)
A grid or bar structure under the mesh pad, sized to carry the wet pad weight without sagging between supports. Open area is kept high so drained liquid does not pond on the grid.
Hold-down grid / bars
Fitted above the pad to stop it lifting or fluidising at high gas velocity. Usually lighter than the support grid, with the same open-area requirement.
Vane pack support frame
A frame that carries vane bundles at the correct angle and spacing, with drainage channels so separated liquid leaves the pack instead of being re-entrained.
Wall seal and bypass prevention
Ring detail, gasket or packed seal between the element edge and the vessel wall. This is the single most common cause of poor demister performance in service.
Specifications
| Parameter | Detail |
|---|---|
| Type | Support grid, hold-down grid, vane pack frame, wall seal ring |
| Materials | SS304, SS316L, duplex, PP, PVDF, PTFE, FRP |
| Design inputs | Vessel ID, demister type and thickness, gas velocity, liquid load |
| Open area | High free area to avoid ponding and hold-up on the grid |
| Segmentation | Split for manway entry; bolted joints inside the vessel |
| Accessories | Lifting handles, fasteners in matching material, gaskets |
Available Materials
SS304 · SS316L · Duplex stainless steel · PP · PVDF · PTFE · FRP
Typical Applications
- Knock-out drums and separator vessels
- Absorber and scrubber tops
- Evaporator and crystalliser vapour outlets
- Compressor suction scrubbers
- Columns with wire mesh or vane mist eliminators
Selection & Design Notes
- Give us the gas velocity at the design case and the turndown case. Hold-down requirements come from the highest velocity the pad will see, not the average.
- Say which way the flow runs. Upflow needs a hold-down grid as well as a support; downflow does not.
- Drainage path matters as much as strength. A grid that traps liquid re-entrains it into the gas, which reads as a demister failure even though the mesh is fine.
- The wall seal is not optional. Specify how the element edge closes against the vessel — a few millimetres of gap is enough for a measurable bypass.
- If the vessel is already built, send the nozzle and support ring dimensions. Most retrofits fail on fit, not on design.
How the Options Compare
A support grid alone is enough for low-velocity upflow duty. Add a hold-down grid wherever gas velocity could lift the pad, which is most revamps and most high-capacity scrubbers. Vane packs need a purpose-built frame with drainage rather than a grid, because their separation depends on the gas turning inside the bundle.